As of May 2026, 44 of 51 US jurisdictions require talk-and-text emergency phones in elevators. Two codes drive it. ASME A17.1-2019 introduced two-way video and text messaging for elevator communication, carried forward in the 2022 and 2025 editions. IBC 2018 and IBC 2021 add enhanced two-way communication requirements for new construction, and IBC 2021 references ASME A17.1-2019 directly. A jurisdiction that has adopted either ASME A17.1-2019 or later, or IBC 2018 or later, requires talk-and-text.

What ASME A17.1-2019 requires in the car

Section 2.27 of ASME A17.1 governs elevator emergency communication. The baseline in 2.27.1.1.1 has been in place for years: two-way voice between the car and an authorized receiver, hands-free with no handset to pick up, one dedicated button marked with the phone symbol that places the call by itself, a receiver that can tell which building and which car is calling, a line only the receiver can hang up, and automatic rollover to a second receiver if nobody answers in 45 seconds.

Section 2.27.1.1.3 is what changed in the 2019 edition, and it is the part most buildings miss. Every passenger car now needs two-way text on the car panel, so a passenger who is deaf, hard of hearing or non-verbal can be reached. It needs video that shows a passenger anywhere on the car floor, including someone lying on the ground. It needs a message in the car confirming the call connected and someone is on the line, and a status the receiver can push back to the car telling the passenger help is on the way.

A phone that only rings out on voice does not meet the 2019 edition. That is the single most common gap on a modernization project: the existing cab phone works, so nobody questions it, and it fails inspection because there is no text or video path.

Text and video are not a 60-foot rule

This is worth reading twice. The text and video requirements in 2.27.1.1.3 apply to every passenger elevator you own, in a three-story building exactly the same as a thirty-story one.

The 60-foot threshold is a different requirement. Section 2.27.1.1.4 applies to buildings with a rise of 60 feet or more and calls for a separate system at the designated level for responders who are physically in the building. That is in addition to the in-car phone, not instead of it, and it also needs text and video at the lobby position.

Do elevators have to have a phone?

Yes, in every US jurisdiction. The real question is which edition of the code your Authority Having Jurisdiction has adopted, because that determines whether voice alone is still acceptable. In the 44 jurisdictions listed below it is not, for new construction or major modernization.

Does an elevator need a dedicated phone line?

Historically yes, and that line was copper POTS. That is now changing under building owners. Carriers are retiring copper POTS service, and buildings running elevator phones over a dedicated analog line are being told the line is going away.

Two things matter when that happens. First, the replacement path has to keep working when building power or the building network fails, which is the whole point of the requirement. Second, if the phone is being replaced anyway, it has to meet the edition in force today, not the edition that applied when the original was installed. A POTS transition is almost always a talk-and-text upgrade as well.

It is also worth knowing what analog cannot do. A POTS line cannot carry text or video, and it cannot be encrypted. Cellular is only as good as the signal in the hoistway. IP and SIP can carry all three and support TLS and SRTP, but then the switches, PoE injectors and gateway have to sit on backup power too.

Backup power and automatic line testing

Section 2.27.1.1.5 requires four hours of backup power for the communication system and one hour for audible signaling devices. The backup has to cover the whole path, not just the phone itself. On an IP system that means the network gear behind it as well.

Section 2.27.1.1.6 requires the system to verify its own line automatically and keep working after a partial outage. That is a system requirement, not a person with a clipboard riding 24 cars once a month. The code requires the test but does not say who hears about a failure, so name that person in writing yourself.

Where talk-and-text is required, state by state

The status below reflects statewide adoption as of May 2026. Home-rule cities may enforce a different edition locally, so always confirm with the AHJ for the project address.

44 of 51 require talk and text 5 not yet 2 set locally

Elevator emergency phone talk-and-text requirement by US jurisdiction, current as of May 2026.
StateTalk and text requiredWhat triggers it
AlabamaYesStatewide ASME A17.1-2019.
AlaskaYesIBC 2021 adopted statewide is the active trigger; the standalone elevator code is ASME 2016.
ArizonaYesStatewide ASME 2019. Phoenix locally enforces ASME 2016 plus IBC 2018.
ArkansasNot yetThe statewide code is IBC 2012 based and the elevator code predates ASME 2019.
CaliforniaYesCal/OSHA Title 8 references ASME 2004, but CBC 2022 on an IBC 2021 base is the trigger for new construction.
ColoradoYesStatewide ASME 2019 with IBC 2021 in force.
ConnecticutYesStatewide ASME A17.1-2019.
DelawareLocal ruleCounty or municipal rules govern; confirm the edition with the local AHJ.
District of ColumbiaNot yetDC operates on the 2017 Construction Codes, a 2015 IBC family, and the elevator code predates ASME 2019.
FloridaYesStatewide ASME 2019 via Rule 61C-5.001.
GeorgiaYesStatewide ASME 2019.
HawaiiYesStatewide ASME 2019 with IBC 2018 in force.
IdahoYesStatewide ASME A17.1-2019 or later.
IllinoisYesStatewide ASME 2019. Chicago locally enforces ASME 2016.
IndianaNot yetThe statewide code is IBC 2012 based and the elevator code predates ASME 2019.
IowaYesStatewide ASME A17.1-2019 via Iowa Administrative Code Chapter 72.
KansasYesStatewide ASME A17.1-2019 or later.
KentuckyNot yetThe Kentucky Building Code is IBC 2015 based and the elevator code predates ASME 2019.
LouisianaYesStatewide ASME 2019 with IBC 2021 in force.
MaineYesIBC 2021 is the active trigger; the standalone elevator code is older.
MarylandYesStatewide ASME 2019 with IBC 2018 in force.
MassachusettsYesThe 10th edition State Building Code on an IBC 2021 base is the active trigger.
MichiganYesIBC 2021 is the active trigger; the standalone elevator code is ASME 2016.
MinnesotaYesThe 2020 State Building Code on an IBC 2018 base is in force statewide.
MississippiYesStatewide ASME 2019.
MissouriNot yetNo statewide commercial building code and the statewide elevator code is ASME 2016.
MontanaYesStatewide ASME 2019 with IBC 2021 in force.
NebraskaYesIBC 2018 is the active trigger; the standalone elevator code is dated.
NevadaYesStatewide ASME 2019.
New HampshireYesStatewide ASME A17.1-2019 or later.
New JerseyYesStatewide ASME 2019.
New MexicoYesStatewide ASME 2019 with IBC 2021 in force.
New YorkYesThe 2025 Uniform Code took effect December 31, 2025. New York City enforces its own code separately.
North CarolinaYesStatewide ASME 2019.
North DakotaYesIBC 2021 is the active trigger; the standalone elevator code is dated.
OhioYesStatewide ASME 2019.
OklahomaYesStatewide ASME A17.1-2019 or later.
OregonYesStatewide ASME 2019.
PennsylvaniaYesStatewide IBC 2018 is the active trigger. The standalone elevator code was updated effective July 2025.
Rhode IslandYesIBC 2018 is the active trigger; the standalone elevator code is on 2016.
South CarolinaYesStatewide ASME 2019 with IBC 2021 in force.
South DakotaYesStatewide ASME 2019.
TennesseeYesTennessee adopted the statewide 2021 IBC effective August 17, 2025.
TexasLocal ruleNo statewide commercial building code and the TDLR elevator code is ASME 2016. Houston, Dallas, Austin, San Antonio and Fort Worth set their own, most on IBC 2021, which requires talk-and-text. Confirm the city code.
UtahYesIBC 2021 is the active trigger; the standalone elevator code is on 2016.
VermontYesThe 2025 Fire and Building Safety Code on an IBC 2021 base is in force statewide.
VirginiaYesStatewide ASME 2019.
WashingtonYesIBC 2018 is the active trigger. Seattle locally enforces ASME 2019.
West VirginiaYesIBC 2018 is the active trigger; the standalone elevator code is dated.
WisconsinYesThe 2021 Commercial Building Code on an IBC 2021 base applies statewide to public buildings and places of employment.
WyomingYesStatewide ASME 2019 with IBC 2021 in force.

Two things decide this, not one. A state can adopt ASME A17.1 directly, or it can adopt a building code edition that pulls the requirement in. Where the adopted IBC edition is newer than the standalone elevator code, the IBC is the operative trigger, and that is what this table reports. Home rule cities can enforce a different edition than their state, so confirm with the AHJ for the project address.

‍

Major metro areas where the city code governs

Large home-rule cities enforce their own building codes, and several run ahead of their state edition. For projects in these metros, confirm the city code directly.

New York City. Required. The NYC Building Code has required two-way audio, two-way text and video for new elevators and major modernizations since June 2023, enforced through the city's own code.

Chicago. Required. Chicago's elevator code mandates two-way communication with a text and visual option, enforced independently of the Illinois state code.

Los Angeles. Required. Operates under the Los Angeles City Building Code on a 2022 California Building Code base.

Boston. Required. Follows the Massachusetts State Building Code on an IBC 2021 base.

Las Vegas. Required. Adopts ASME A17.1-2019 with local amendments.

Seattle. Required. Locally enforces ASME A17.1-2019, ahead of the Washington state edition.

Six questions to ask before you sign off

Who picks up at 2am? Get the primary receiver and the failover in writing.

How does it connect? POTS, cellular, or IP and SIP. Analog cannot carry text or video.

Where does the video land, and who is allowed to watch it?

Does IT manage the device, or is it on the network with no owner?

Who tests it, how often, and where do you see the record?

Which code edition did your AHJ adopt? Adoption lags publication by years and it drives everything above.

Methodology and scope

A jurisdiction is classified Required when its standalone elevator code references ASME A17.1-2019 or later, or when IBC 2018 or later is in force statewide. Not Yet Required covers jurisdictions whose statewide elevator code predates ASME A17.1-2019 with no statewide IBC 2018 trigger. Varies Locally covers jurisdictions with no statewide code, where county or municipal rules govern. Classifications reflect statewide adoptions as enforced by state departments of labor, state fire marshals and state building code commissions as of May 2026. This page is a general reference. It is not legal advice and it is not a substitute for consultation with the Authority Having Jurisdiction for your project address. Download the full PDF below, which adds a color-coded map, or contact LiftComm for help specifying a compliant elevator communication system.

Get a Quote or Schedule a demo